澳客鼻胃管采用医用TPU(聚氨酯)材料制成,专为最佳喂养而设计。这些鼻胃管用于为无法通过吞咽获得营养和食物的患者提供食物或营养。鼻饲管可以通过鼻子或嘴插入并放置在胃、十二指肠或空肠中。
专业医用级聚氨酯 NG 管。具有易于插入的管芯和不透射线条纹。抗扭结,不含乳胶,有多种 Fr 尺寸可供选择。肠内喂养具有卓越的生物相容性。
透明聚氨酯饲管,带有 1/2/3 条不透射线和标记(3 条不透明线在 X 射线下产生最佳可见度并增强安全性)。
聚氨酯鼻胃管带PH试纸导丝采用医用级聚氨酯(TPU)材质,配备pH试纸导丝、亲水涂层、X射线成像功能及多种接头选项,适用于临床肠内营养输注。产品具备精准定位、安全舒适、操作便捷等特点,满足医护人员及患者的个性化需求。
点击放大
| 序号 | 产品名称 | 产品型号 | 管径(mm) | 长度(cm) | 支/中盒 | 支/件 | 配置 |
| 1 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-2.0mm(Fr6)H | 2.0 | 50~80 | 10 | 100 | 包埋単钡线;导丝引导;鼻贴(备选) |
| 2 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-2.7mm(Fr8)H | 2.7 | 60~90 | |||
| 3 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-3.3mm(Fr10)H | 3.3 | 110~140 | |||
| 4 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-4.0mm(Fr12)H | 4.0 | ||||
| 5 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-4.7mm(Fr14)H | 4.7 | 110~125 | |||
| 6 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-5.3mm(Fr16)H | 5.5 | ||||
| 7 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-6.0mm(Fr18)H | 6.0 | ||||
| 8 | 聚氨酯鼻胃管带PH试纸导丝 | AKBit-R(L)-6.7mm(Fr20)H | 6.7 | ||||
| 9 | 客户定制 联系我们 | ||||||
The nasogastric tube is a medical device used for enteral nutrition and gastric decompression. This nasogastric tube is made of medical-grade TPU, which offers excellent biocompatibility, softness, and durability. Unlike traditional PVC or silicone tubes, TPU provides superior patient comfort and reduces mucosal irritation during long-term use. The tube is designed for single use, eliminating the risk of cross-contamination between patients.
This nasogastric tube features a patented pH test paper guidewire, which is a domestic first. This innovative design allows clinicians to verify tube placement without aspirating gastric fluid. Simply remove the guidewire and compare the color change of the pH test paper to confirm correct positioning. This simplifies the verification process, saves valuable clinical time, and enhances patient safety. The guidewire is made of 304 stainless steel with a fine spring construction, providing optimal flexibility and pushability during insertion. Its smooth, rounded tip minimizes the risk of damaging the catheter wall, ensuring the integrity of the tube throughout the procedure.
The catheter tip is coated with a hydrophilic coating that forms a highly lubricating hydrogel film upon contact with water. This reduces frictional resistance between the catheter and the digestive tract mucosa during insertion, completely eliminating the risk of pre-insertion friction. Applying paraffin oil or petroleum jelly can cause secondary contamination to patients. The coating significantly improves patient comfort and reduces trauma to nasal and esophageal tissues.
For radiological confirmation, the nasogastric tube incorporates an X-ray imaging function with an embedded radiopaque line. Depending on different customer needs, we can provide single barium, double barium, triple barium, and full radiopaque options. The tube tip is equipped with a high barium ratio gravity head, providing the same imaging and focusing effect under X-ray, making it easier to determine the tube position. This feature ensures precise placement and reduces the risk of mispositioning.
The nasogastric tube is also available with multiple connector types to accommodate different enteral feeding pumps and infusion devices. This flexibility allows healthcare providers to choose the most suitable connection method based on their clinical workflow and patient needs. Standard connectors are compatible with most feeding systems, reducing the need for additional adapters.
The manufacturing process follows strict quality control standards to ensure product safety and reliability. Each tube undergoes rigorous testing for mechanical strength, chemical resistance, and biocompatibility before packaging and sterilization. The tube is designed with clear depth markings to assist with accurate placement. The packaging is designed for easy opening and aseptic presentation, saving valuable time in busy clinical environments.
Proper positioning of the nasogastric tube is critical for both patient safety and treatment efficacy. Misplacement can lead to serious complications, including aspiration pneumonia. The pH test paper guidewire provides an immediate and reliable visual indicator of correct placement, significantly reducing the risk of error. This is particularly beneficial in emergency or intensive care settings where time and accuracy are essential.
The design of this nasogastric tube has been developed with extensive clinical feedback to meet the real-world needs of healthcare professionals. The tube’s flexibility and kink resistance make it suitable for long-term use, minimizing the need for replacement and reducing overall patient discomfort. The materials are carefully selected for compatibility with enteral feeding formulas and gastric fluids.
Patient safety is the top priority in the design of this nasogastric tube. The radiopaque line ensures clear visibility under X-ray for quick confirmation of tube position. The materials used are safe and reliable, suitable for patients with allergies or sensitivities. These features make this nasogastric tube a reliable choice for healthcare providers who prioritize both safety and clinical efficiency.
Continuous innovation drives the development of this nasogastric tube. The manufacturer invests in research and development to improve product performance and patient outcomes. Feedback from healthcare professionals is actively sought and incorporated into the design process. This commitment to quality has established this product as a trusted solution in healthcare institutions worldwide.
Choose this nasogastric tube for its combination of advanced materials, innovative design, and practical clinical features. With customizable sizing, optional accessories, and a strong commitment to quality, this product is designed to support better patient outcomes and streamline daily nursing procedures. For more information about nasogastric tube placement and clinical guidelines, refer to PubMed resources or contact our team for assistance.